The Right Response
By Lucas Vazques, S.E., P.E., Structural Senior Project Engineer, S. A. Miro, Inc.
Choosing the best R value in moderate seismic regions is a case-by-case decision
with lots of factors. These tips can help.
STRUCTURAL ENGINEERS working in seismic regions have an extra set of factors to consider.
They must balance performance, constructability, cost, and code compliance when selecting a lateral force-resisting system. In Seismic Design Category C, engineers are often presented with multiple code-permitted options that appear similar on paper but lead to significantly different design paths in practice.
One instance is choosing if a system’s assigned response modification factors, or R values, will be 3 or 3.25. While the numerical difference between the two is relatively small, the implications can be substantial, and engineers in moderate seismic regions must understand when each system is appropriate.
The R Factor
The response modification factor, R, is a primary tool in seismic design and accounts for a structure’s anticipated inelastic behavior during an earthquake. It reduces the seismic forces engineers are required to design for under the assumption that the structural system will dissipate energy through controlled deformation rather than remain entirely elastic.
Higher R values correspond to larger reductions in design seismic force. In theory, a higher R factor allows engineers to design structures for lower seismic demands, potentially reducing member sizes and overall material usage. However, it also implies greater reliance on ductile behavior, which introduces additional code requirements intended to ensure the structure performs as expected during a seismic event.
An R = 3 system generally represents a structural system that is not specifically detailed for seismic resistance. An R = 3.25 system is commonly associated with an ordinary concentrically braced frame (OCBF), which carries additional seismic detailing and verification requirements intended to achieve a greater level of ductility.
Seismic Force
At first glance, the higher-R system may appear advantageous because it permits reduced seismic loading. However, the actual reduction between R = 3 and R = 3.25 is relatively modest. Because seismic base shear is inversely proportional to the response modification factor, the ratio of the two systems is 3.0/3.25 = 0.923, meaning the R = 3.25 system reduces design base shear by only about 7.7%. A structure designed for 100 kips of seismic base shear using R = 3 would be designed for approximately 92 kips using R = 3.25.
Base shear represents the cumulative lateral force generated by ground acceleration as the building mass responds to seismic motion. These forces develop throughout the structure and ultimately transfer into the foundation and surrounding soil. Although reducing base shear can theoretically produce a lighter and more efficient structural design, the limited reduction associated with the move from R = 3 to R = 3.25 often does not significantly alter the final structural system.
Drift
One reason for limited differences between the two R values is that in Seismic Design Category C, drift limitations frequently govern the design regardless of the selected R factor. Drift refers to the relative displacement between adjacent levels of a structure during seismic loading. In a one-story building, drift is measured as the movement of the roof relative to the foundation. In taller structures, drift is measured between consecutive floors.
Building codes impose drift limits to protect structural and non-structural components from excessive movement during earthquakes. In many projects, these allowable drift limits become the controlling design criterion rather than the overall seismic force itself. As a result, even though an R = 3.25 system permits somewhat lower design forces, engineers may still need to size members similarly to satisfy stiffness and drift requirements.
Drift considerations often lead to a situation where the theoretical benefit of the higher R factor produces little meaningful reduction in structural weight or cost while still introducing additional design obligations.
Ductility
The primary trade-off associated with the R = 3.25 OCBF system is the increased level of detailing and code compliance required to achieve the system’s intended ductile performance. Ductility refers to a structure’s ability to deform without sudden failure during seismic loading. Systems with higher ductility can absorb and dissipate more energy, which is why they are permitted to use larger reductions in seismic force.
Achieving that ductility, however, requires more engineering design and detailing practices. One of the most significant differences involves protected zones defined in the AISC Seismic Provisions for Structural Steel Buildings (ANSI/AISC 341-22). Protected zones are portions of structural members that are expected to experience inelastic deformation during an earthquake. Because these areas are critical to the intended seismic behavior of the system, certain attachments and modifications are restricted.
For example, contractors may be prohibited from attaching non-structural components directly to these protected elements if doing so could interfere with the member’s ability to deform as intended. While these requirements improve seismic reliability, they can also create additional coordination challenges among structural engineers, architects, mechanical designers, and contractors during both design and construction.
Additional Checks
The OCBF system also introduces additional engineering checks related to overstrength and force transfer. Under seismic loading, certain structural members may experience forces substantially larger than those used in standard design calculations. To account for this behavior, engineers must verify that critical elements can resist the maximum forces that surrounding braces and beams can develop.
A key distinction is that many seismic design checks are not based solely on the reduced code-level seismic forces used to size the lateral-force-resisting system. Instead, the AISC Seismic Provisions require certain elements and connections to be designed using either an overstrength seismic load or a capacity-limited seismic load. The overstrength seismic load is determined using an overstrength factor, Ω0, that is specified by ASCE 7 for the chosen seismic force-resisting system. For a capacity-limited seismic load, the engineer assumes designated ductile elements will yield and designs surrounding components to remain essentially elastic.
The OCBF system does not automatically require capacity-limited design, which would require designing the elements that are expected to remain elastic based on the expected strength of the brace. Instead, the required strengths of beams, beam connections, and brace connections may be determined using the overstrength seismic load. AISC Seismic Provisions Sections F1.5c and F1.6a contain those requirements, and AISC Seismic Provisions Section B2 further explains that, when overstrength seismic load is required, it is determined using the overstrength factor, Ω0. Engineers are then permitted to use the capacity-limited seismic load instead when this capacity-limited seismic load is lower than the load determined using the overstrength factor.
For OCBFs, designing for the capacity-limited seismic load requires that brace connections, gusset plates, collectors, columns, anchors, and transfer elements are checked using the expected strength of the brace rather than the force obtained directly from the equivalent lateral force procedure. Expected brace strength incorporates material overstrength through the Ry factor and may also include strain-hardening effects. Consequently, connection design forces can be significantly larger than the nominal seismic design forces that originally sized the brace.
Consider a brace with a specified yield strength of 50 ksi and a gross area of 8 sq. in., which has a nominal yield strength of 400 kips. Applying a typical Ry factor of 1.1 increases the expected yield strength to 440 kips before considering additional strain-hardening effects. Connections and surrounding force-transfer elements may therefore need to be designed for forces considerably higher than those suggested by the reduced seismic design base shear alone.
As a result, engineers frequently find that gusset plate thicknesses, weld sizes, bolt quantities, base plate dimensions, anchor rod sizes, and collector forces are governed by capacity-design requirements rather than by the approximately 7.7% reduction in base shear associated with moving from R = 3 to R = 3.25. In these situations, the theoretical force reduction produces little practical reduction in fabrication effort or construction cost.
While the capacity-design philosophy improves overall seismic resilience, it also increases engineering effort and complexity. Additional calculations, detailing requirements, and coordination tasks can extend design schedules and increase project costs.
Choosing a System
Ultimately, selecting the appropriate seismic system requires evaluating more than the numerical reduction in seismic force alone. Engineers must consider constructability, detailing complexity, coordination demands, review requirements, and overall project efficiency alongside structural performance objectives. When both systems are permitted by code, the simpler R = 3 approach can often provide a more streamlined and practical design path. Although there are circumstances where the additional ductility and detailing associated with an OCBF system may be appropriate or required, many projects in Seismic Design Category C do not gain enough benefit from the higher R factor to justify the increased complexity.
In practice, the most efficient structural solution is not always the one associated with the highest theoretical performance factor. Simpler systems can provide reliable seismic performance while reducing coordination challenges, engineering effort, and construction complications. For structural engineers navigating moderate seismic design conditions, understanding this balance remains an important part of delivering economical and constructible projects that still satisfy the intent of the building code.
about the author

Lucas Vazquez, P.E., S.E.
Published online Modern Steel Construction Magazine
Lucas Vazquez, P. E., S. E. is a Structural Senior Project Engineer at S. A. Miro, Inc.